Publicado ago 18, 2011



PLUMX
Google Scholar
 
Search GoogleScholar


Diana Marcela Achury Saldaña

Gloria Judith Sepúlveda

Sandra Mónica Rodríguez Colmenares

##plugins.themes.bootstrap3.article.details##

Resumen

Introducción: se describe la construcción y validación inicial de un isntrumento para evaluar la capacidad de agencia de autocuidado en el paciente con hipertensión arterial, basándose en la teoría de autocuidado de Dorotea Orem. Consta de 17 ítems agrupados en tres dimensiones (capacidades fundamentales, componentes de poder y capacidad de operar el autocuidado). Métodos: el instrumento fue aplicado a 159 personas con diagnóstico de hipertensión arterial. Se estableció la validez del constructo a través del análisis factorial y la consistencia interna por medio del test estadístico alfa de Cronbach. Resultados: el análisis psicométrico de este estudio mostró  un índice de confiabilidad para el cuestionario total de 0,75, el cual se considera adecuado; a pesar de que el resultado del análisis factorial mostró que las dimensiones propuestas por los autores no se ajustan a los factores obtenidos por el método de extracción de componentes principales. Conclusión: este instrumento se convierte en una herramienta de valoración de enfermería que puede ser útil para evaluar capacidad de agencia de autocuidado en pacientes con hipertensión arterial. Es importante continuar con el proceso de validación, dado que la evidencia empírica apoya la evaluación del constructo general, pero no por dimensiones según lo propuesto en el modelo de Dorotea Orem.

 

ABSTRACT

Introduction: this paper describes the initial construction and validation of an instument used to evaluate the capacity of self-care in patients with hypertension. The instrument is based on Dorothea Orem's Theory of Self-Care and is comprised of 17 items grouped into three dimensions: fundamental capacities; power components; and capacity of self-care management. Methods: the instument was administered to 159 people with hypertension. Construct validity was established using factorial analysis and internal hypertension. Construct validity was established using factorial analysis and internal consistency was determined by the Cronbach alpha statistical test. Results: the instrument showed a Cronbach alpha of 0.75, which is considered appropiate, even though the results of the factor analysis showed that the dimensions proposed by the authors did not meet the factors obtained by the extraction method of principal components. Conclusion: findings show that the instument could be used as a nursing evaluation tool. The instument can help identify the self-care management capacity of patients wit hypertension as well as assist in the creation of individual patient care plans. It is important, however, to continue the validation process since the empirical evidence supports the general assessment of the construct but not the dimensions as proposed in the model by Dorothea Orem.

Keywords

Validez, Instrumento, Hipertension, Hypertension

References
Cómo citar
Achury Saldaña, D. M., Sepúlveda, G. J., & Rodríguez Colmenares, S. M. (2011). Instrumento para evaluar la capacidad de agencia de autocuidado en pacientes con hipertensión arterial. Investigación En Enfermería: Imagen Y Desarrollo, 11(2), 9–25. Recuperado a partir de https://revistas.javeriana.edu.co/index.php/imagenydesarrollo/article/view/1615
Sección
Artículos Originales de Investigación

Artículos más leídos del mismo autor/a

1 2 3 > >>