Abstract

Introduction: Positioning uncertainties are found in patients during treatment of radiotherapy. This study was conducted in order to show the experience in our center. 

Methods: 316 patients were analyzed in the period from March 17 to June 18, 2010, which compared the images DRR (Digitally Reconstructed Radiographs) with radiological images either by X-ray film or digital image for performing
corrections in the three axes. 

Results: 809 images were recorded in 316 patients, mostly in prostate cancer. En 91% of the images made no corrections required during the treatment,
positioning corrections in all three axes (X, Y, Z) was 3.4 mm, however corrections of 5 mm or more in obesity patients was found. 

Conclusion: In this study we found a suitable reproduction for our patients during treatment with uncertainties positioning similar to those reported
in the literature, the greater quantity was founded in patients treated with prostate cancer. Special attention should be paid in obese and very thin
patients who may require improved immobilization technique.

PDF (Spanish)

Ploeger LS, Frenay M, Betgen A, van Herk M. Application of video imaging for improvement of patient set-up. Radiother Oncol. 2003;68:277-84.

Bert C, Metheany KG, Doppke KP, Powell SN. Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients. Int J Radiat Oncol Biol Phys. 2006;64:1265-74.

Krengli M, Gaiano S, Mones E, Beldi D, Loi G. Reproducibility of patient

setup by surface image registration system in conformal radiotherapy of

prostate cancer. Radiation Oncol. 2009;4:1-10.

Serago EF, Buskirk SJ, Gale A, Earle J. Comparison of daily megavoltaje electronic portal imaging or kilovoltaje imaging with marker sedes to ultrasound imaging or skin mars for prostate localization and treatment positioning in patients with prostate cancer. Int J Radiat Oncol Biol Phys. 2006;65:1585-92.

Cranmer G. A treatment planning investigator into the dosimetric effects of systematic prostate patient rotational set-up errors. Med Dosim. 2008; 33:199-205.

Gordon J, Crimaldi A, Hagan M, Siebers J. Evaluation of clinical margins in simulation of patient setup errors in prostate IMRT treatment plans. Med Phys. 2007;34:202-14.

Kupelian PA, Lee C, Meeks SL. Evaluation of image-guidance strategies in the treatment of localized prostate cancer. Int J Radiat Oncol Biol Phys. 2008;70:1151-7.

Hurkmans CW, Remeijer P, Leberque J, Mirjnheer B. Set-up verification using portal imaging; review of current clinical practice. Radiother Oncol. 2001;58:105-20.

Fiorino C, Reni M, Bolognesi A, Calandrino R. Set-up error in supinepositioned patients immobilized with two different modalities during conformal radiotherapy of prostate cancer. Radiother Oncol. 1998; 49:133-41.

Wong JR, Gao Z, Uematsu M, Merrick S, Cheng CW. Interfractional prostate shifts: Review of 1870 computed tomography (CT) scans obtained during image-guided radiotherapy using CTon rails for the treatment of prostate cancer. Int J Radiat Oncol Biol Phys. 2008;72:1376-401.

This journal is registered under a Creative Commons Attribution 4.0 International Public License. Thus, this work may be reproduced, distributed, and publicly shared in digital format, as long as the names of the authors and Pontificia Universidad Javeriana are acknowledged. Others are allowed to quote, adapt, transform, auto-archive, republish, and create based on this material, for any purpose (even commercial ones), provided the authorship is duly acknowledged, a link to the original work is provided, and it is specified if changes have been made. Pontificia Universidad Javeriana does not hold the rights of published works and the authors are solely responsible for the contents of their works; they keep the moral, intellectual, privacy, and publicity rights.

Approving the intervention of the work (review, copy-editing, translation, layout) and the following outreach, are granted through an use license and not through an assignment of rights. This means the journal and Pontificia Universidad Javeriana cannot be held responsible for any ethical malpractice by the authors. As a consequence of the protection granted by the use license, the journal is not required to publish recantations or modify information already published, unless the errata stems from the editorial management process. Publishing contents in this journal does not generate royalties for contributors.